Information Summary
|
Product
|
Max Cap
|
Estimated Monthly Production
|
Start Order Date
|
Est. Delivery Date
|
|
MW-2200™
|
10 kW
|
2200 kWh
|
February 2008
|
4th Quarter 2008
|
· Productivity: 2200 kWh/month in a 13 mph average wind, on a house with a UDA factor of 1.9. (See Wind Energy for a discussion on UDA).
· Name Plate: Median 10 kW rated output in 28 mph wind at sea level with 80% relative humidity on a house with a UDA factor of 1.9.
· Weight: 800 - 1000 pounds depending on sails selected.
· Height: 8-12 feet depending on sails selected.
· Diameter: 10-14 feet depending on sails selected.
· Sail Sizes:
· Small Sail 9’8” X 10’2”
· Large Sail 12’6” X 14’
· Hawaii Sail 8’ X 14’
· Cut-In Speed: Less than 5 mph, on a house with a UDA factor of 1.9.
· Top Speed: Maximum rated speed 120 mph at turbine.
· Temperature:
· Turbine Operating Temperature -45˚ F to 130˚F
· Inverter Operating Temperature 32˚ F to 113˚ F
· Hook-up :
· Small FRP enclosure/J-box (6”X6”X4”) that fits under the roof modification, and to which conduit can be channelled for the down-wiring.
· Output Wiring is 14-4 wiring from the turbine to the inverter.
· Electrical, from Turbine:
· Voltage 0-480 volts
· Amperage 0-10 Amps
· Wattage max depends on number of coil packs selected. Calculated with sail size.
· Electrical, from Inverter:
· MEDCOM/CPE_ AC/AC converters modules with grid connection each rated at 10kW
· Installed in a wall mounted enclosure for 10 kW Wind system with output Voltage from permanent magnets, 3-phase axial flux alternator.
· Converter specification:
· Wall Mounted
· Sine wave grid connected inverter with uo to 50% overload capacity
· Inverter output Voltage: Single phase, 208 Vac, +10% / -15%, 240 Vac, +10% / -15% and 220 Vac, +10% / -15%
· Rated Frequency: 50 Hz. +0.5Hz and 60 Hz, +0.6Hz
· Rated Output Power: 10 kW
· Rated Output current harmonics: <4%
· Anti-islanding contactor between inverter and electrical grid
· AC/DC and DC/AC conversion efficiency between 90% and 95%
· Power Factor: Unity P.F.
· Ambient temperature: 0 to 45C
· Auto reconnect (restart) after power interruption
· Includes dumpload resistors
· Includes DC terminals for connection to optional DC/DC converters and batteries, if required.
Note: batteries and optional DC/DC converters not included in price.
· Approvals: cUL, CE. Meets UL1741 and IEEE1547.
· Equipment manufactured in ISO facility
· Maintenance and Operation Costs: Minimal
· Deployment: Rooftop Urban or Rural Setting.
· Total Estimated Production Run 2008: 320 Units
· Production Units Ready for delivery 4th Quarter 2008. First 60 will be shipped in October 2008.